24 1440psi Sour Vertical Separator 3 Phase
Supporting Documents (3)
library_booksConstructed with Alberta, Sask, & BC Registration
100°F design temperature
Inlet diverter and float hood
4” thick x 9 lb/ft3 mistex
Radiography: RT-1,
Designed 3 phase/Dressed 2
Fully Flanged vessel
VESSEL CONNECTIONS:
N1 Gas Inlet 1 - 3” NPS 600 ansi Flange
N2 Gas Outlet 1 - 3” NPS 600 ansi Flange
C1 Drain 1 - 2” NPS 600 ansi Flange
C2 Condensate LLC 1 - 2” NPS 600 ansi Flange
C3 Water LLC 1 - 2” NPS 600 ansi Flange
C4 Condensate Outlet 1 - 2” NPS 600 ansi Flange
C5 Water Outlet 1 - 2” NPS 600 ansi Flange
C6 a/b LG - Condensate 2 - 2” NPS 600 ansi Flange
C7 a/b LG - Water 2 - 2” NPS 600 ansi Flange
C8 PI 1 - 2” NPS 600 ansi Flange
C9 TI 1 - 2” NPS 600 ansi Flange
C10 PSV 1 - 2” NPS 600 ansi Flange
C11 Inspection 2 - 2” NPS 600 ansi Flange
SENIOR METER RUN C/W FLOW CONDITIONER
3” 600# Flanged outer ends, Sch 80
SOUR. Service trim
10% Radiography
Built to AGA 2000 Edition
One (1) - 1” 3000# T.O.L. and one (1) 3/4” 3000# T.O.L. downstream